Comparative study of laminated glass fins using full-scale testing, finite element modeling, and buckling formulas glassonweb.com - get the latest breaking news, showbiz & celebrity photos, sport news & rumours, viral videos and top stories from glassonweb.com Daily Mail and Mail on Sunday newspapers.
Post breakage strength of glass is still an unknown area as analytical models for this are inconclusive so far and thus destructive testing is the only reliable solution.
In the past glass design in Switzerland was based on foreign standards and regulations. Questions raised whether the application of these standards is suitable, as they do not comply with the Swiss Standard SIA 260 –Basis of design. The most used standards are the German technical regulations for the use of glazing with linear supports (TRLV) and the DIN 18008. The Swiss society of engineers and architects (SIA) initiated a structural glass standard committee with the task to develop a Swiss glass design standard.
The new Swiss glass design standard is based on the same concept as the Eurocode10 Design of Structural Glass , which is currently in preparation. In future, this standard will be the basis of the Swiss national annex of the Eurocode. An important issue in glass design practice is the shear coupling effect in laminated glass. The standard allows taking into the shear coupling effects and thus will lead to more economic pane thickness.A new concept was developed to m