Lets tip it up a little bit. Priority a. W. G. 63 type s. O. O. W 600 volt sunlight and water resistant. Which means what . It means its a cord rather than a cable or wire. The cord is not to be used for permanent wiring. This is a cord that is designed for temporary power. Its a big cord. It is, its 50 amp. What do they mean when they say primary . I dont know what it means. American wire gauge, the six is the size of the aware, the 3 is the three conductors, the type s. O. O. W. , thats extra hard use cord. The w stand for wet. 600 volts is the volts its good for and in the sun and underwater. Its 90 degrees centigraderated. It can run as high as 180 degrees without deterioration. This can get really hot. What would you use this cord for . Temporary power for construction. I see, ok. Or you might use it for example, on a peer when you need a flexible wiring method to get from the shore to the pier. You are allowed to use cord wiring. It would be permanent its an exception to the gene
Installing. Two sets of these or one set of 500s. When somebody orders this grounding electrode, how much do they usually order . By national code, we need 20 feet. 20 feet has to be buried. In the rebar. We need 20 feet. So whatever we need longer, we can cut extra. So 20 feet plus what it takes to get. Whatever they want to. Cut us off a little bit. David, lets talk about Energy Efficiency. I know fluorescent lights and bulbs are a big issues right now. People are changing oldstyle fluorescent bulbs. Whats the old one, the new one and the savings . The standard of the industry were t12. This was a fourfoot lamp. The 12 stands for and and its about four or five times more efficient than the typical incandescent light bulb. In the energy to increase Energy Efficiency. They have a more efficient standard. Its a two footer. Its called the t8. Its half an inch in diameter. These are bipin fluorescent fixtures. These are 10, 15 for efficient than the older t12. All of the fixtures bought n
That comes from the panel board that only supplies the receptacles that youre going to be using for the computer or sensitive equipment is one answer. You want to make sure that you install that circuit, the wires are remote from any radio frequency devices or any other circuits that might impose a radio frequency on them. What kind of wires would impose a radio frequency . It could be a computer, another computer, it could be the microwave oven. You want to separate is from any other ideally. If youre running your wires in a raceway or an armored cable that uses ferrous metal, that protects those conductors against these radio frequencies much better than nonmetallic cable. That would be another strategy. And then if youre in a commercial installation where it is really, really important, you put in isolation transformers adjacent to the equipment. Thats the most expensive solution but the best solution is to actually put an isolation device right at your equipment. They also have fil
ALLEGANY — Allegany Rescue and EMS Inc. officials, volunteers and guests attended a groundbreaking Monday afternoon for the new Rescue and EMS headquarters at the site of the former St.